<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>occupational hygine and health promotion journal</title>
<title_fa>بهداشت کار و ارتقاء سلامت</title_fa>
<short_title>ohhp</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ohhp.ssu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2588-2643</journal_id_issn>
<journal_id_issn_online>2588-3062</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>6</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی شدت روشنایی در مدارس ابتدایی شهرستان بجنورد در سال 1395</title_fa>
	<title>A Survey on the Intensity of Lighting in Elementary Schools of Bojnurd City</title>
	<subject_fa>آماری</subject_fa>
	<subject>Statistical</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;line-height:20.0pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;زمینه و هدف&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot;&gt; روشنایی مطلوب باید تعادلی بین اقتصاد و محیط پیرامون ایجاد کند. به منظور رعایت اصول ایمنی و سلامت کارکنان باید روشنایی مناسب برای محیط کار جهت انجام وظایف روزمره تأمین گردد. شرایط نامناسب روشنایی موجب مخدوش شدن اطلاعات بصری محیطی و افزایش احتمال اشتباه در کار می&#8204;شود. کیفیت روشنایی در ایجاد رغبت جهت تحصیل و آسایش بصری و بهره&#8204;وری در فرآیند یادگیری دانش آموزان اهمیت به سزایی دارد. موضوع این پژوهش نحوه و میزان روشنایی در مدارس شهر بجنورد در مراکز آموزشی ابتدایی و ارزیابی کیفیت روشنایی مدارس و شناسایی مشکلات موجود در دستگاه&#8204;های روشنایی مدارس و ارائه&#8204;ی راهکارهای مناسب جهت بهبود می&#8204;باشد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:20.0pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;روش بررسی&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;:&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;این &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;مطالعه توصیفی در مدارس ابتدایی دخترانه شهر بجنورد در مقطع زمانی پاییز ۱۳۹۵ در ۱۰ مدرسه در مناطق مختلف شهر به صورت تصادفی انتخاب شد و میزان روشنایی کل (طبیعی و مصنوعی) و طبیعی به صورت جداگانه با استفاده از دستگاه لوکس متر &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;Hanger CE&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;اندازه&#8204;گیری صورت گرفت. داده&#8204;های جمع آوری شده که شامل شدت روشنایی کل، طبیعی و مصنوعی کلاس&#8204;ها بود توسط نرم&#8204;افزار &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;SPSS&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; (ورژن ۱۸) مورد تجزیه و تحلیل قرار گرفتند و برای هر کلاس میانگین شدت روشنایی و انحراف معیار برحسب لوکس محاسبه گردید و همچنین نوع لامپ&#8204;ها، معیوب بودن لامپ&#8204;ها، رنگ دیوارها و سطح دستگاه&#8204;ها و تجهیزات مدرسه مورد بررسی قرار گرفت.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:20.0pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;یافته&#8204;ها&lt;/span&gt;&lt;/b&gt;&lt;span dir=&quot;LTR&quot;&gt;:&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; نتایج نشان می&#8204;دهد که در ۹۰ درصد موارد بررسی شده شدت روشنایی کل با مقادیر استاندارد مطابقت داشت و در ۱۰ درصد موارد شدت روشنایی کل مطابق با استاندارد نبود. ۵۷/۸۷ درصد موارد نوع لامپ&#8204;ها برای روشنایی محوطه و کلاس&#8204;ها مناسب بود، در ۹/۵ درصد موارد لامپ&#8204;ها سوخته و معیوب بودند.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;نتیجه&#8204;گیری&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;: عدم وجود روشنایی مطلوب طبیعی و مصنوعی در مدارس به دلیل جانمایی نادرست پنجره&#8204;ها و توزیع نامناسب لامپ&#8204;ها و همچنین نسبت سطح به پنجره را می&#8204;توان از دلایل وضعیت نامناسب سیستم بهره&#8204;وری روشنایی دانست.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;line-height:16.0pt&quot;&gt;&lt;b&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;Background and Aim&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;: Optimal lighting should create a balance between economy and the environment&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt; In order to comply with safety and health principles of the staff, proper lighting of the work environment should be provided for everyday tasks&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt; Inappropriate lighting conditions cause distortion of environmental visual information, and increase the likelihood of mistakes in the work&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt; The quality of lighting is important for creating willingness to study, visual comfort, and productivity in the learning process of students&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt; The subject of this research is the manner and intensity of lighting in schools, in the city of Bojnurd, in elementary education centers. It, also, tries to assess the quality of lighting schools, identify problems in school lighting systems, and provide appropriate solutions for improvement&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:16.0pt&quot;&gt;&lt;b&gt;Materials and Methods&lt;/b&gt;: This descriptive study was randomly selected in girl&amp;rsquo;s elementary schools of Bojnourd, during autumn of 1395, in 10 schools in different regions of the city. &lt;span lang=&quot;EN&quot;&gt;The overall lighting (natural and artificial) and natural light were measured individually, using the Hanger CE Lux Meter&lt;/span&gt;.&lt;span lang=&quot;EN&quot;&gt; Collected data, including total brightness, natural, and artificial of classes, were analyzed by SPSS software (version 18). For each class, the minimum, maximum and average brightness and standard deviation were calculated based on the lux. Also, the type of lamps, defective lamps, wall colors and the quality of devices and equipment were studied.&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:16.0pt&quot;&gt;&lt;b&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span style=&quot;letter-spacing:.2pt&quot;&gt;Results&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span style=&quot;letter-spacing:.2pt&quot;&gt;: Results showed that in 90% of cases, the intensity of lighting was consistent with standard values, and in 10% of cases, the lighting intensity was not in accordance with the standard. In 87.57% of the cases, the type of lamps was suitable for lighting of the school and classes, and in 94.1% of the cases the lamps were burned out and defective.&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;letter-spacing:.2pt&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;b&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;letter-spacing:.2pt&quot;&gt;Conclusion&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;EN&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;letter-spacing:.2pt&quot;&gt;: The lack of natural and artificial lighting in schools due to the incorrect placement of windows, inappropriate distribution of lamps, as well as the ratio of the surface to the window, are the causes of inappropriate status of lighting efficiency system.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract>
	<keyword_fa>مدارس ابتدایی, شدت روشنایی, لوکس‌متر</keyword_fa>
	<keyword>School, Lux Meter, Quality of Lightimgg</keyword>
	<start_page>88</start_page>
	<end_page>98</end_page>
	<web_url>http://ohhp.ssu.ac.ir/browse.php?a_code=A-10-88-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Faeze</first_name>
	<middle_name></middle_name>
	<last_name>SEPAHI ZOERAM</last_name>
	<suffix></suffix>
	<first_name_fa>فائزه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سپاهی زوارم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>fs.day16@yahoo.com</email>
	<code></code>
	<orcid>0000-0002-0024-6743</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Occupational Health Research Center, Department of Occupational Health Engineering and Safety, School of Public Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran</affiliation>
	<affiliation_fa>مرکز تحقیقات بهداشت حرفه ای، گروه مهندسی بهداشت حرفه ای و ایمنی کار، دانشکده بهداشت، دانشگاه علوم پزشکی شهید صدوقی یزد، یزد، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Fateme</first_name>
	<middle_name></middle_name>
	<last_name>PAKRAVAN</last_name>
	<suffix></suffix>
	<first_name_fa>فاطمه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پاکروان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid>0000-0002-8365-1751</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Environmental Health Engineering, School of Public Health, North Khorasan University of Medical Sciences, Bojnurd, Iran</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی خراسان شمالی، بجنورد، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Morteza</first_name>
	<middle_name></middle_name>
	<last_name>ESMAILZADE KAVAKI</last_name>
	<suffix></suffix>
	<first_name_fa>مرتضی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اسماعیل زاده کواکی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m_kavaki@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Occupational Health Engineering and Safety, School of Public Health, North Khorasan University of Medical Sciences, Bojnurd, Iran</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت حرفه ای و ایمنی کار، دانشکده بهداشت، دانشگاه علوم پزشکی خراسان شمالی، بجنورد، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Neda </first_name>
	<middle_name></middle_name>
	<last_name>VAHIDI</last_name>
	<suffix></suffix>
	<first_name_fa>ندا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>وحیدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid>0000-0003-1440-9459            </orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Environmental Health Engineering, School of Public Health, North Khorasan University of Medical Sciences, Bojnurd, Iran</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی خراسان شمالی، بجنورد، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
